Chengdu Guoguang Elecric Co.,Ltd

Chengdu Guoguang Elecric Co.,Ltd Hardworking, Pioneering, Vigorous and Innovative

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Digital Vacuum Controller /

One Circuit Digital Vacuum Controller Hot Cathode Ionization Vacuum Meter Type

Contact Now
Chengdu Guoguang Elecric Co.,Ltd
Visit Website
City:chengdu
Province/State:sichuan
Country/Region:china
Contact Person:MrDai
Contact Now

One Circuit Digital Vacuum Controller Hot Cathode Ionization Vacuum Meter Type

Ask Latest Price
Video Channel
Brand Name :GUOGUANG
Model Number :ZDL-ZDR-10B
Place of Origin :Sichuan, China (Mainland)
MOQ :Negotiation
Price :Negotiation
Payment Terms :T/T
Supply Ability :200 Pieces per Month
Delivery Time :10 days(less than 50pcs)
Packaging Details :Export Packing: Carton box
Pressure Range :1.0×10 2—1.0×10-4(Pa)
Testing precision :±10%
Equipped gauge :resistance gaugeM014/CF35
Control precision :±1%
Control time :< 1S
Humidity :≤85%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Thermocouple Vacuum Controller

Hot Cathode Ionization Vacuum Meter

Type: ZDR-10B

Thermocouple Vacuum Controller:

ZDR-10B ionization vacuum gauge can test one circuit vacuum gauge sign and has two circuits control contact output. In the testing range, it can be point control and area control freely. It is suitable to be used in testing and controlling the vacuum of wide measuring range.

It adopts the most advanced microprocessor as its main machine, improving its reliability by decreasing external components. Its hardware employs the modular structure, EMI restraint and WATCHDOG circuit; while the software employs anti-interference technique, such as redundancy, trap, digital filtering and so on to improve its anti-interference ability and performance, which ensures the high reliability of the apparatus and its normal use in bad industrial environment.

Parameter

1 Testing circuit quantity one circuit
2 Testing range 1.0×102—1.0×10-4 (Pa)
3 Ionization parameters

Voltage of Positive pole:165V

Emission current: 500uA/50uA

4 Testing precision ±10%
5 Zero drift ±2%
6 Controlling range 1.0×102—1.0×10-4 (Pa)
7 Controlling method Two circuits point control or area control
8 Controlling precision ±1%
9 Controlling time < 1S
10 Output contend 3A/220VAC non-inductive load
11 Analog output 0-5V/4-20mA(nil)
12 Power supply AC 220V/50Hz ±10%
13 Environmental temperature -10℃--45℃
14 Environmental Humidity < 85%(25℃)
15 Rated consumed power 35W
16 Net weight of the apparatus About 3.5Kg
Inquiry Cart 0